Chlorination System M 20 RC

Products

The M 20 RC Chlorinator System is designed for dosing gas chlorine and with minor alterations other gases, working on the indirect vacuum principle.

Add to inquiry list

Capacity up to 15kg/h

Vacuum principle

GENERAL

The M 20 RC Chlorinator System is designed for dosing gas chlorine and with minor alterations other gases, working on the indirect vacuum principle.

The M 20 RC System consists of:

  • M 20 C  vacuum regulator with rate valve
  • M 300 C ejector

Dosing can be set manually with the rate valve on the regulator. It starts or stops when the ejector pump switches on/off.

INSTALLATION

It is very simple to mount vacuum regulators. However, installation of the devices must be done by qualified experts, taking in consideration all required international standards in order to ensure safe and faultless operation.

An authorized service must overhaul the system once a year.

Options

Alarm
yes "A", without alarm the letter is not written in the code
Regulator
"R", means system with all general parts
Gas Type
“C” - Cl2, “CO2” - CO2, “S” - SO2, “N” - NH3
Ejector
"B" - DPT: ejector with PVC valves designed for pool engieneering (pressure up to 6bar)
"T" - reinforced ejector: is used with pressure higher than 6 bar
"P" - Ejector with connection cock: for dismantling under pressure (up to 3 bar, max 4 kg/h)
Pressure Gauge
yes "M", without it the letter is not written in the code
Yoke
for clamp type yoke, the letter "F" is written in the code

Dosing range (g/h)

1
up to 12
2
up to 25
3
up to 100
4
up to 200
5
up to 500
6
up to 1000
7
up to 2000
8
up to 4000
9
up to 10000
15
up to 15000

Technical data

Accuracy
Withing 4% of the flow
Operating range
20:1
Weight
Nett: 4,7kg, Gross: 7,4kg
Packaging Dimensions
600 x 400 x 400mm

Connections

Vacuum (up to 15m)
2kg/h
d8/d10 - 3/8"
4kg/h
d8/d10 - 3/8"
10kg/h
d12/d16 - 5/8"
15kg/h
d12/d16 - 5/8"

For larger vacuum lines, see table: Chlorine vacuum line size requirements.

 

Connection to the cylinder: 1” (complies with DIN  477)

Ejector connection:

See product info for ejectors M 300.